X-ray and gamma-ray weld examination — AELB licensed radiation operations across Malaysia and Brunei.
RT uses ionizing radiation (X-rays or gamma rays) to produce images of the internal structure of components, revealing porosity, inclusions, cracks and lack of fusion in welds.
PetroNDT holds AELB radiation licenses. We use Iridium-192 (Ir-192) gamma sources for field and offshore work, and X-ray for controlled environments.

Establish radiation safety zone and position source and film/detector.
Expose film or digital detector for calculated time based on source activity and material thickness.
Process radiographic film or acquire digital image.
Qualified Level II/III interpreter evaluates the radiograph against acceptance criteria.
Issue RT report with image reference, findings and accept/reject status.