Level II/III interpretation of radiographic film and digital images to ASME, API and AWS acceptance standards.
Radiographic Interpretation is the skilled reading and evaluation of radiographic images to identify, classify and accept or reject weld discontinuities against applicable code acceptance criteria.
PetroNDT provides dedicated RT interpretation by ASNT Level II and Level III certified interpreters — both for our own RT operations and as a third-party service for client film archives and digital images.

Verify IQI (penetrameter) sensitivity meets code requirements before interpretation.
Check film density is within acceptable range using densitometer.
Evaluate radiograph systematically from left to right, identifying all indications.
Classify each indication by type, location, size and orientation.
Compare findings against applicable code acceptance criteria and issue report.